ANALISIS ENERGI DAN EKSERGI SISTEM RANKINE ORGANIK DAN SISTEM REFRIGERASI KOMPRESI UAP YANG TERINTEGRASI

FERDYSON, Ferdyson and Fajar TK, Berkah and Sutaryo, Sutaryo (2025) ANALISIS ENERGI DAN EKSERGI SISTEM RANKINE ORGANIK DAN SISTEM REFRIGERASI KOMPRESI UAP YANG TERINTEGRASI. Masters thesis, UNIVERSITAS DIPONEGORO.

[thumbnail of Hal Cover Ok-1.pdf] Text
Hal Cover Ok-1.pdf

Download (33kB)
[thumbnail of Hal Cover Ok.pdf] Text
Hal Cover Ok.pdf
Restricted to Repository staff only

Download (558kB)
[thumbnail of BAB I PENDAHULUAN.pdf] Text
BAB I PENDAHULUAN.pdf

Download (739kB)
[thumbnail of BAB II TINJAUAN PUSTAKA.pdf] Text
BAB II TINJAUAN PUSTAKA.pdf

Download (468kB)
[thumbnail of BAB III METODOLOGI PENELITIAN.pdf] Text
BAB III METODOLOGI PENELITIAN.pdf
Restricted to Repository staff only

Download (580kB)
[thumbnail of BAB IV.pdf] Text
BAB IV.pdf
Restricted to Repository staff only

Download (1MB)
[thumbnail of BAB V KESIMPULAN DAN SARAN.pdf] Text
BAB V KESIMPULAN DAN SARAN.pdf
Restricted to Repository staff only

Download (212kB)
[thumbnail of DAFTAR PUSTAKA.pdf] Text
DAFTAR PUSTAKA.pdf

Download (158kB)

Abstract

Pemanasan global telah menjadi isu yang mendapatkan perhatian seluruh dunia, diperlukan segera mengambil tindakan secapat mungkin dalam mengurangi emisi gas rumah kaca. Seperti menggunakan energi terbarukan dan baru terbarukan, salah satunya pemanfaatan panas limbah dari panas buang yang dihasilkan oleh mesin exhaust keramik.
Penelitian ini bertujuan untuk menganalisis energi dan eksergi dari sistem gabungan organic rankine cycle (ORC) dan vapor compression refrigeration (VCR) pada aplikasi pemanfaatan panas limbah mesin pendingin keramik yang menggunakan beberapa jenis refrigeran berbeda. Penelitian ini menggunakan pendekatan kuantitatif dengan motode rumus-rumus pendekatan energi dan eksergi yang diaplikasikan ke dalam software engineering equation solver (EES) untuk disimulasikan. Ada beberapa parameter sistem untuk digunakan dalam simulasi seperti temperatur, efisiensi dan lajur aliran udara dari exhaust, bertujuan untuk menghitung performa kinerja sistem keseluruhan dan kerusakan eksergi yang terjadi didalam setiap komponen.
Hasil analisis termodinamika menunjukkan bahwa refrigeran R152a merupakan pilihan terbaik untuk digunakan dalam sistem ini yang merupakan sistem gabungan organic rankine cycle (ORC) dan vapor compression refrigeration (VCR) pada aplikasi pemanfaatan panas limbah mesin pendingin keramik. Koefisien kinerja sistem (COP sistem) dari sistem ini sebesar 0,6122 dan koefisien kinerja eksergi sebesar 0,5017. Siklus VCR mampu menghasilkan kapasitas pendinginan sebesar 16,25 kW. Dengan efisiensi organic rankine cycle (ORC) sebesar 0,1114 %. Total energi yang dihasilkan sebesar 0,7699 kW serta kerusakan eksergi total sebesar 2.166 kW.

Global warming has emerged as a critical issue receiving worldwide attention, necessitating immediate action to reduce greenhouse gas emissions. One promising approach is the utilization of renewable and alternative energy sources, including waste heat recovery from engine exhaust systems, such as those in ceramic cooling machines. This study aims to conduct energy and exergy analyses of a combined Organic Rankine Cycle (ORC) and Vapor Compression Refrigeration (VCR) system applied to the recovery of waste heat from a ceramic cooling engine, employing several types of refrigerants. A quantitative method is adopted, utilizing energy and exergy balance equations implemented in Engineering Equation Solver (EES) software for simulation purposes. Key system parameters such as exhaust temperature, efficiency, and airflow rate are incorporated to evaluate the overall performance and quantify exergy destruction within each system component.The thermodynamic analysis indicates that R152a is the most suitable refrigerant for the combined ORC–VCR system in the context of ceramic engine waste heat recovery. The system demonstrates a coefficient of performance (COP) of 0.6122, with an exergy efficiency of 0.5017. The VCR subsystem delivers a cooling capacity of 16.25 kW, while the ORC subsystem achieves a thermal efficiency of 0.1114%. The total energy output is 0.7699 kW, and the cumulative exergy destruction across the system is 2.166 kW

Item Type: Thesis (Masters)
Uncontrolled Keywords: Energi, Eksergi, Sistem Rankine Organik, Sistem Refrigerasi Kompresi Uap, Terintegrasi