EFEK LAJU AIR UMPAN TEKANAN RENDAH SEBAGAI PEMANAS UDARA MASUK TURBIN GAS TERHADAP EFISIENSI ENERGI DAN EKSERGI PADA PEMBANGKIT LISTRIK TENAGA GAS DAN UAP DI BEBAN PARSIAL

ADITYA, Adha and Widayat, Widayat and Harmoko, Udi (2026) EFEK LAJU AIR UMPAN TEKANAN RENDAH SEBAGAI PEMANAS UDARA MASUK TURBIN GAS TERHADAP EFISIENSI ENERGI DAN EKSERGI PADA PEMBANGKIT LISTRIK TENAGA GAS DAN UAP DI BEBAN PARSIAL. Masters thesis, UNIVERSITAS DIPONEGORO.

[thumbnail of COVER.pdf] Text
COVER.pdf

Download (146kB)
[thumbnail of COVER LENGKAP.pdf] Text
COVER LENGKAP.pdf
Restricted to Repository staff only

Download (1MB)
[thumbnail of BAB I.pdf] Text
BAB I.pdf

Download (321kB)
[thumbnail of BAB II.pdf] Text
BAB II.pdf

Download (867kB)
[thumbnail of BAB III.pdf] Text
BAB III.pdf
Restricted to Repository staff only

Download (510kB)
[thumbnail of BAB IV.pdf] Text
BAB IV.pdf
Restricted to Repository staff only

Download (1MB)
[thumbnail of BAB V.pdf] Text
BAB V.pdf
Restricted to Repository staff only

Download (247kB)
[thumbnail of DAFTAR PUSTAKA.pdf] Text
DAFTAR PUSTAKA.pdf

Download (294kB)
[thumbnail of LAMPIRAN.pdf] Text
LAMPIRAN.pdf
Restricted to Repository staff only

Download (739kB)

Abstract

Profil operasional sistem kelistrikan Indonesia menuntut Pembangkit Listrik Tenaga Gas dan Uap (PLTGU) untuk beroperasi secara dominan pada kondisi beban parsial, yang berimplikasi pada penurunan efisiensi termal sistem. Penelitian ini mengkaji pengaruh penerapan pemanas udara masuk terintegrasi yang memanfaatkan air umpan tekanan rendah (low-pressure feedwater) dari siklus air–uap terhadap kinerja PLTGU tipe GE 9HA.02 yang beroperasi pada beban 55%. Evaluasi kinerja dilakukan melalui analisis komparatif energi dan eksergi berbasis data operasional aktual, yang selanjutnya divalidasi menggunakan simulasi perangkat lunak DWSim untuk menentukan tingkat pemanasan udara masuk yang optimal. Hasil penelitian menunjukkan bahwa aktivasi pemanas udara masuk meningkatkan efisiensi termal pembangkit dari 59,49% menjadi 60,76% serta menghasilkan penurunan bersih laju destruksi eksergi sistem sebesar 10,5 MW. Perbaikan kinerja ini terutama disebabkan oleh penurunan signifikan destruksi eksergi pada ruang bakar dan kompresor, masing-masing sebesar 9,4 MW dan 2,8 MW, yang secara keseluruhan melampaui peningkatan kerugian eksergi pada komponen pembangkit lainnya. Hasil simulasi menunjukkan bahwa pemanasan udara masuk hingga temperatur 46,7 °C menghasilkan keuntungan termodinamika maksimum, sementara peningkatan temperatur hingga 48,1 °C masih memberikan peningkatan efisiensi dibandingkan kondisi tanpa pemanasan namun menunjukkan penurunan setelah melampaui titik optimum tersebut. Temuan ini menegaskan bahwa strategi pemanasan udara masuk terintegrasi merupakan pendekatan yang efektif dan tervalidasi untuk meningkatkan kualitas konversi energi serta kinerja PLTGU pada kondisi operasi beban parsial.
Kata Kunci: Pembangkit Listrik Tenaga Gas dan Uap, Pemanas udara masuk, Operasi beban parsial, Efisiensi termal, Analisis eksergi

The operational profile of the Indonesian power system requires combined cycle gas turbine (CCGT) power plants to operate predominantly under part-load conditions, which leads to a degradation in overall thermal efficiency. This study investigates the impact of an integrated inlet air heating system utilizing low-pressure feedwater from the water–steam cycle on the performance of a GE 9HA.02 CCGT operating at 55% load. Performance evaluation was conducted through comparative energy and exergy analyses based on actual operational data, which were further validated using DWSim simulations to determine the optimal inlet air heating level. The results indicate that activation of the inlet air heater increases the plant thermal efficiency from 59.49% to 60.76% and yields a net reduction in the total exergy destruction rate of 10.5 MW. This performance improvement is primarily attributed to significant reductions in exergy destruction within the combustion chamber and compressor by 9.4 MW and 2.8 MW, respectively, which collectively outweigh the increase in exergy losses in other plant components. Simulation results show that inlet air heating up to 46.7 °C provides the maximum thermodynamic benefit, while further heating to 48.1 °C still results in higher efficiency compared to the unheated condition but exhibits a decline after exceeding the optimal point. These findings confirm that an integrated inlet air heating strategy is an effective and validated approach for enhancing energy conversion quality and improving CCGT performance under part-load operation.
Keywords: Combined Cycle Gas Turbine, Inlet air heater, Part-load operation, Thermal efficiency, Exergy analysis

Item Type: Thesis (Masters)
Uncontrolled Keywords: Pembangkit Listrik Tenaga Gas dan Uap, Pemanas udara masuk, Operasi beban parsial, Efisiensi termal, Analisis eksergi
Subjects: Engineering
Divisions: Postgraduate Program > Master Program in Energy
Depositing User: ekana listianawati
Date Deposited: 23 Feb 2026 07:14
Last Modified: 23 Feb 2026 07:14