Search for collections on Undip Repository

STUDI POTENSI PENGHEMATAN ENERGI PADA TERMINAL PENYIMPANAN BBM PT. PETRO STORINDO ENERGI DI KUTAI TIMUR, KALIMANTAN TIMUR

WIBOWO, Kun and Windarta, Jaka and Suedy, Sri Widodo Agung (2025) STUDI POTENSI PENGHEMATAN ENERGI PADA TERMINAL PENYIMPANAN BBM PT. PETRO STORINDO ENERGI DI KUTAI TIMUR, KALIMANTAN TIMUR. Masters thesis, UNIVERSITAS DIPONEGORO.

[thumbnail of Hal Cover-1.pdf] Text
Hal Cover-1.pdf

Download (392kB)
[thumbnail of Hal Cover.pdf] Text
Hal Cover.pdf
Restricted to Repository staff only

Download (743kB)
[thumbnail of BAB I.pdf] Text
BAB I.pdf

Download (368kB)
[thumbnail of BAB II.pdf] Text
BAB II.pdf

Download (487kB)
[thumbnail of BAB III.pdf] Text
BAB III.pdf
Restricted to Repository staff only

Download (295kB)
[thumbnail of BAB IV.pdf] Text
BAB IV.pdf
Restricted to Repository staff only

Download (1MB)
[thumbnail of BAB V.pdf] Text
BAB V.pdf
Restricted to Repository staff only

Download (390kB)
[thumbnail of daftar pustaka.pdf] Text
daftar pustaka.pdf

Download (433kB)
[thumbnail of Lampiran.pdf] Text
Lampiran.pdf
Restricted to Repository staff only

Download (587kB)

Abstract

Konservasi energi penting dilakukan untuk pengembangan teknologi dan kehidupan modern dan sangat berdampak kepada peningkatan kinerja energi pada peralatan atau sistem yang menggunakan energi yang sangat besar.
Penelitian ini dilakukan dengan menggunakan metode ISO 50002:2014 yang mana merupakan standar untuk mendefinisikan persyaratan-persyaratan minimum yang mengarah pada identifikasi peluang-peluang peningkatan (improvement) kinerja energi seperti menentukan EnPI (Energy Performance Indicator), menentukan SEU (Significant Energy Uses), dan mengevaluasi kinerja energi peralatan pengguna energi.
Di dalam aktivitas Perusahaan, energi yang dikonsumsi adalah 93,88% energi listrik dan 6.12% solar dengan Significant Energy Uses (SEU) adalah sistem HVAC-1 (22,92%), UPS (21,09%) dan HVAC-2 (19,52%). Dan beban listrik yang besar lainnya adalah UPS dan lighting (17,81% dan 14,64%). Jika dikelompokkan sesuai fungsinya, maka beban terbesar adalah HVAC (42,44%) dan Lighting (21,96%).
Nilai EnPI dalam aktivitas berkisar 0,0031-0,0049 GJ/kL dengan biaya energi rata-rata sebesar Rp. 49.368.512,-/bulan dan intensitas biaya produktivitas sebesar Rp. 1.176,99,-/kL. Untuk aktivitas kantor rata-rata sebesar Rp. 8.496.860,-/bulan dengan intensitas biaya energi sebesar Rp. 24.207,58,-/m2/bulan.
Untuk meningkatkan kinerja energi yang optimal maka Perusahaan dapat menargetkan nilai EnPI pada kisaran 0,0022 GJ/kL dengan nilai penyaluran B35 sebesar 47.000-53.000 kL/bulan. Peningkatan kinerja ini dapat dilakukan dengan melakukan perbaikan kualitas tegangan listrik, penggantian lampu pada ruang kerja dan manajemen energi sistem pengkondisian udara.
Kata Kunci: konservasi energi, EnPI, SEU, ISO 50002:2014, HVAC

Energy conservation is important for the development of technology and modern life and has a significant impact on improving energy performance in equipment or systems that use very large amounts of energy.
This study was conducted using the ISO 50002:2014 method, which is a standard for defining minimum requirements that lead to identifying opportunities to improve energy performance such as determining EnPI (Energy Performance Indicator), determining SEU (Significant Energy Use), and measuring energy performance in equipment that uses energy.
In the Company's activities, the energy consumed is electrical energy of 93.88% and solar power of 6.12% with Significant Energy Uses (SEU) being the HVAC-1 system (22.92%), UPS (21,09%) and HVAC-2 (19.52%). And if categorize by functions, the largest electrical loads is HVAC (42,44%) and Lighting (21,96%).
The EnPI value for activities ranges from 0.0031-0.0049 GJ/kL with an average energy cost of Rp. 49,368,512,-/month and productivity cost intensity of Rp. 1,176.99,-/kL. For office activities, the average is Rp. 8,496,860,-/month with energy cost intensity of Rp. 24,207.58,-/m2/month.
To improve optimal energy performance, the Company can target the EnPI value in the range of 0.0022 GJ/kL with a B35 distribution value of 47,000-53,000 kL/month. This performance improvement can be done by improving the quality of electrical voltage, replacing lamps in the work space, and managing energy in the air conditioning system.
Keywords: energy conservation, EnPI, SEU, ISO 50002:2014, HVAC

Item Type: Thesis (Masters)
Uncontrolled Keywords: konservasi energi, EnPI, SEU, ISO 50002:2014, HVAC