Search for collections on Undip Repository

ANALISIS STRATEGI NET ZERO ENERGY BUILDING DENGAN DESAIN AKTIF UNTUK SISTEM PENCAHAYAAN, PENGONDISI UDARA SERTA PENGGUNAAN PHOTOVOLTAIC DI GEDUNG PERKANTORAN

ZULRAMADHANIE, Zulramadhanie and Windarta, Jaka and Cahyadi, Cahyadi (2024) ANALISIS STRATEGI NET ZERO ENERGY BUILDING DENGAN DESAIN AKTIF UNTUK SISTEM PENCAHAYAAN, PENGONDISI UDARA SERTA PENGGUNAAN PHOTOVOLTAIC DI GEDUNG PERKANTORAN. Masters thesis, UNIVERSITAS DIPONEGORO.

[thumbnail of Halaman Cover_Ok.pdf] Text
Halaman Cover_Ok.pdf

Download (1MB)
[thumbnail of BAB I.pdf] Text
BAB I.pdf

Download (393kB)
[thumbnail of BAB II.pdf] Text
BAB II.pdf

Download (1MB)
[thumbnail of BAB III.pdf] Text
BAB III.pdf
Restricted to Repository staff only

Download (1MB)
[thumbnail of BAB IV.pdf] Text
BAB IV.pdf
Restricted to Repository staff only

Download (6MB)
[thumbnail of BAB V.pdf] Text
BAB V.pdf
Restricted to Repository staff only

Download (49kB)
[thumbnail of DAFTAR PUSTAKA.pdf] Text
DAFTAR PUSTAKA.pdf

Download (1MB)

Abstract

Meningkatnya konsumsi energi dan emisi disektor bangunan, sehingga berdampak pada perubahan iklim dan pemanasan global. Strategi dari masalah tersebut yaitu net zero energy building (NZEB) dengan parameter pentingnya yaitu efisiensi energi dan penggunaan energi terbarukan. Pemerintah Indonesia mengeluarkan PERMEN ESDM No.2 Tahun 2024. Dalam studi ini, peraturan tersebut difokuskan pada peraturan ekspor energi listrik ke jaringan (PLN), dimana pada PERMEN ESDM No. 26 Tahun 2021 ekspor energi dengan nilai jual kembali sebesar 65% dari tarif dasar listrik (TDL), sebaliknya pada peraturan terbaru ekspor energi listrik tidak diperhitungkan atau 0 Rupiah. Studi dilakukan di Gedung 620 dan 621 PRKKE-BRIN, untuk sistem pencahayaan didominasi lampu tabung (TL) jenis fluoresen sehingga kurang efisien, sedangkan untuk pengondisi udara (AC) menggunakan tipe split dengan kapasitas 1-2 PK, dimana berdasarkan pengamatan awal beberapa unit AC tidak berfungsi dengan baik. Rata-rata radiasi matahari harian di lokasi ini sebesar 4,76 (kWh/m²/hari). Oleh karena itu, diperlukan kajian sebagai pilot project konsep NZEB dengan menganalisis strategi desain aktif untuk sistem pencahayaan dan pengondisi udara mengunakan pendekatan potensi penghematan energi dengan metode pengukuran dan verifikasi disalah satu ruangan yang akan diganti dengan peralatan yang lebih efisien yang melibatkan pengujian lampu dan AC yang dianalisis untuk memenuhi kriteria NZEB serta tekno-ekonomi mengunakan software RETScreen. Strategi penggunaan energi terbarukan mengunakan sistem photovoltaic (PV) dengan menganalisis area efektif diarea gedung menggunakan software Helioscope untuk mengetahui kapasitas maksimal serta analisis bayangan. Software Homer mensimulasikan dua sistem PV yaitu sistem on-grid dengan kapasitas PV 132 kWp dan sistem hybrid dengan kapasitas PV140,8 kWp mengunakan baterai OPzV dengan kapasitas 282 kWh serta tekno-ekonomi menggunakan sensitifitas penjualan kembali peraturan saat ini sebesar 0% dan sebelumnya sebesar 65 % ditambahkan sensitifitas 15,25,35,45,55 %. Hasil analisis potensi penghematan energi pertahun dari penggantian lampu TL adalah sebesar 14.139 kWh dengan pengembalian biaya modal selama 1,9 tahun, didapatkan peningkatan efisiensi dari 41 lm/W menjadi 112 lm/W, sehingga memenuhi kriteria NZEB pada sistem pencahayaan yaitu = 80 lm/W. Potensi penghematan energi pertahun dari penggantian AC sebesar 27.900 kWh dengan pengembalian biaya modal 3,7 tahun, didapatkan peningkatan efisiensi dari 2,5 menjadi 5,3 Wh/Wh sehingga memenuhi kriteria NZEB pada sistem AC yaitu COP minimum 4,2 Wh/Wh. Kedua penggantian tersebut layak dan memenuhi kriteria NZEB dari desain aktif, selain itu strategi NZEB mengunakan PV didapatkan kedua sistem PV menjadikan gedung mencapai NZEB dengan energi positif pada analisis keseimbangan energi bersih sehingga memenuhi kriteria dari NZEB =0. hasil analisis tekno-ekonomi sistem PV sistem on-grid dengan sensitifitas penjualan Kembali sebesar 45%-65% yang layak dan memenuhi kriteria tekno-ekonomi dengan skema pinjaman, sehingga untuk menerapkan NZEB di Gedung PRKKE-BRIN dengan PERMEN ESDM No.2 tahun 2024, layak diterapkan dengan skema tanpa pinjaman.
Kata Kunci: Pengkondisian Udara, Pencahayaan, Faktor Kinerja Pendinginan Musiman, Efikasi, Sistem Hybrid, Sistem On-grid

The increasing energy consumption and emissions in the building sector result in climate change and global warming. The strategy of the problem is net zero energy building (NZEB) with the important parameters of energy efficiency and the use of renewable energy. The Indonesian government issued MEMR regulation No.2 of 2024. In this study, the regulation is focused on the regulation of exporting electric energy to the grid (PLN), where in MEMR regulation No. 26 of 2021, energy exports with a sell-back value of 65% of the basic electricity tariff (TDL), whereas in the latest regulation the export of electric energy is not calculated or 0 Rupiah. The study was conducted in Building 620-621 PRKKE-BRIN, for the lighting system is dominated by fluorescent tube lights (TL), so it is less efficient, while air conditioning (AC) using a split type with a capacity of 1-2 PK, where based on initial observations several AC units are not functioning properly. The average daily solar radiation at this location is 4.76 (kWh/m²/day). Therefore, a study is needed as a pilot project of the NZEB concept by analyzing active design strategies for lighting and air conditioning systems using an energy-saving potential approach with measurement and verification methods in one room that will be replaced with more efficient equipment involving testing of lamps and air conditioners analyzed to meet NZEB criteria and techno-economics using RETScreen software. Renewable energy strategies using photovoltaic (PV) systems by analyzing the effective area in the building area using Helioscope software to determine the maximum capacity and shadow analysis. Homer software simulates two PV systems, namely an on-grid system with a PV capacity of 132 kWp and a hybrid system with a PV capacity of 140.8 kWp using an OPzV battery with a capacity of 282 kWh and techno-economics using the current regulatory resale sensitivity of 0% and previously at 65% added sensitivity of 15, 25, 35, 45, 55%. The results of the analysis of the potential annual energy savings from replacing TL lamps is 14,139 kWh with a return on capital costs for 1.9 years, obtaining an increase in efficiency from 41 lm / W to 112 lm / W, thus meeting the NZEB criteria on the lighting system which is = 80 lm / W. The potential annual energy savings from replacing the air conditioner amounted to 27,900 kWh with a payback of 3.7 years, an increase in efficiency from 2.5 to 5.3 Wh/Wh was obtained, thus meeting the NZEB criteria for air conditioning systems, namely a minimum COP of 4.2 Wh/Wh. Both replacements are feasible and meet the NZEB criteria of active design. Besides the NZEB strategy using PV, it is obtained that both PV systems make the building achieve NZEB with positive energy in the net energy
Keywords: Air Conditioner, Lighting, Cooling Seasonal Performance Factor, Efficacy, Hybrid System, On-grid System

Item Type: Thesis (Masters)
Uncontrolled Keywords: Pengkondisian Udara, Pencahayaan, Faktor Kinerja Pendinginan Musiman, Efikasi, Sistem Hybrid, Sistem On-grid
Subjects: Engineering
Divisions: Postgraduate Program > Master Program in Energy
Depositing User: ekana listianawati
Date Deposited: 23 Dec 2024 04:47
Last Modified: 23 Dec 2024 04:47
URI: https://eprints2.undip.ac.id/id/eprint/28295

Actions (login required)

View Item View Item